Series A Home >Digital products >Series A
XL807

Introduction:

The dual CPU architecture is used in the kernel of the verification system, and the function is strong, and the bandwidth is greatly expanded with 24BitAD chip and 512 times over sampling technology, and the measurement accuracy is improved. At the same time, the dynamic range and signal to noise ratio are improved by using multi file automatic switch and FIR filter. Use LabView development management software, beautiful interface, easy to use. The power supply and the sampling input adopt a lot of electromagnetic compatibility measures, which can adapt to the complex field test environment. Using the portable design scheme, convenient laboratory and field test.

Main purpose:

To meet the IEC61850 (-9-1, -9-2, -9-2LE) standard for electronic transformer check; check the polarity of the electronic transformer and the delay time; check on the small signal output of electronic transformer; small signal input to the merging unit check; precision voltage signal can be output two 0.05 level 0~7V, without high voltage and large current can rise; small signal input to the merging unit check (extended precision standard source module); can output digital signal source (FT3) format, without the need for high voltage and large current can rise to support the merging unit FT3 input check. (expansion of digital signal source module); can the FT3 output of electronic transformer calibration (extended FT3 conversion module); to check (extended analog signal conversion module of traditional transformer)

Main features:

XL-807 electronic transformer calibration instrument is mainly used in the -9-1 (-9-2, -9-2LE, IEC61850) standard output of electronic transformers for verification. Check items include: ratio difference, phase difference, delay, polarity, etc.. At the same time, a small signal input terminal can be configured to check the small signal output of the electronic transformer and the small signal input of the combined unit for verification, etc..

Main function:

1 use the traditional instrument transformer (BHE) and 3458A Agilent digital multi use table to achieve

Quantity value transfer.

2 can use the built-in GPS or high stability of the crystal output pulse synchronization signal.

3. Packets full frame resolution protocol of IEC 61850 (-9-1, -9-2, -9-2LE), automatic analysis of asdu number and sampling points etc., all channel waveform display without capture can be intuitive to view all the channels of data.

4 with ST/SC dual fiber Ethernet interface and dual RJ45 Ethernet interface, improve reliability, and easy access to different interfaces of electronic transformers.

The 5.6 order quasi synchronization algorithm makes the algorithm error of the non synchronous sampling to be close to zero.

6 using AD 24Bit chip and 512 times over sampling technology, greatly expanding the bandwidth to improve the accuracy.

7 the use of multi file automatic switch and FIR filter to improve the dynamic range and reduce the signal to noise ratio.

8 real-time display waveform, frequency, amplitude, phase and other data to facilitate comprehensive analysis of transformer performance.

9 with industrial control computer, 800*600 touch screen. More convenient operation.

10 equipped with powerful, easy to operate the operation software, can run in industrial control computer or notebook

11 data, such as mean, variation, extreme value and multiple errors, can be used for the stability and linearity of electronic transformers.

12 can carry out multiple harmonic analysis and the electronic type transformer every second harmonic accuracy of calibration.

13 can record and replay the whole test process.

14 for frame tests, real-time statistics of dropped frames.

Technical index:

1 accuracy rating: 0.05 (compared with 0.05%, 2)

2 communication protocol: IEC61850-9-2/ IEC61850-9-2LE IEC61850-9-1/

3 input range

1) voltage range: 100V/ and 100V

2) current range: 5A, 1A

3) small signal input range 200mV, 225mV, 150mV, 4V, 1V, 2V, 1.625V, 3.25V, 4V, 6.5V

4 accurate measurement range

Voltage (V): 5%-120%Un (Un =100/ V 0.05%RD or 100V)

在线客服